<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	
	>
<channel>
	<title>
	Comments on: New Repair Blog By ERG Member	</title>
	<atom:link href="https://jestineyong.com/new-repair-blog-by-erg-member/feed/" rel="self" type="application/rss+xml" />
	<link>https://jestineyong.com/new-repair-blog-by-erg-member/</link>
	<description>Semiconductors, Test Equipments, Circuit Board Troubleshooting, Electronic Repair Courses and Many More!</description>
	<lastBuildDate>Wed, 25 Aug 2010 17:32:10 +0000</lastBuildDate>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.4.19</generator>
	<item>
		<title>
		By: admin		</title>
		<link>https://jestineyong.com/new-repair-blog-by-erg-member/comment-page-1/#comment-6562</link>

		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 25 Aug 2010 17:32:10 +0000</pubDate>
		<guid isPermaLink="false">https://www.jestineyong.com/?p=3063#comment-6562</guid>

					<description><![CDATA[HI Muhammad,

Many of our analog meters have a reverse output from the probes. You can use another digital voltmeter to confirm the polarity. 

Jestine]]></description>
			<content:encoded><![CDATA[<p>HI Muhammad,</p>
<p>Many of our analog meters have a reverse output from the probes. You can use another digital voltmeter to confirm the polarity. </p>
<p>Jestine</p>
<div class="ldc-cmt-box clearfix"><span class='ldc-ul_cont' onclick="alter_ul_post_values(this,'6562','c_like')">Likes<img src="https://jestineyong.com/wp-content/plugins/like-dislike-counter-for-posts-pages-and-comments/images/up.png" />(<span>0</span>)</span><span class='ldc-ul_cont' onclick="alter_ul_post_values(this,'6562','c_dislike')">Dislikes<img src="https://jestineyong.com/wp-content/plugins/like-dislike-counter-for-posts-pages-and-comments/images/down.png" />(<span>1</span>)</span></div>
<div style="clear:both;"></div>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Muhammad Ataullah		</title>
		<link>https://jestineyong.com/new-repair-blog-by-erg-member/comment-page-1/#comment-6555</link>

		<dc:creator><![CDATA[Muhammad Ataullah]]></dc:creator>
		<pubDate>Wed, 25 Aug 2010 02:38:44 +0000</pubDate>
		<guid isPermaLink="false">https://www.jestineyong.com/?p=3063#comment-6555</guid>

					<description><![CDATA[HiMr.yong:I know yours time is very importent,when you feel comfortable you give me replay,Because i am still confused,i tray to compare digtal multimeter and Analog multimeter,i have in my bench very expensive and true rms digital digital mulimeter model number 72-410a of TENMA,i compare ETECH instrument 38070 Analog multimeter  to test diode,inclouding zener diode,power diode,i find oposite result in forward bias,reversed bias,for exp i take power diode,GEin5060 and test from digital meter when i connect blk lead to cathode and red on o anode its showing forawrd bias or you can say forward voltage drop,but if you check from anlog meter you find opposit resullt,i discuss with my co workers he says our digital meter is auto change polarity may me!can you solve this problem.
sorry for yours time
Muhammad Ataullah]]></description>
			<content:encoded><![CDATA[<p>HiMr.yong:I know yours time is very importent,when you feel comfortable you give me replay,Because i am still confused,i tray to compare digtal multimeter and Analog multimeter,i have in my bench very expensive and true rms digital digital mulimeter model number 72-410a of TENMA,i compare ETECH instrument 38070 Analog multimeter  to test diode,inclouding zener diode,power diode,i find oposite result in forward bias,reversed bias,for exp i take power diode,GEin5060 and test from digital meter when i connect blk lead to cathode and red on o anode its showing forawrd bias or you can say forward voltage drop,but if you check from anlog meter you find opposit resullt,i discuss with my co workers he says our digital meter is auto change polarity may me!can you solve this problem.<br />
sorry for yours time<br />
Muhammad Ataullah</p>
<div class="ldc-cmt-box clearfix"><span class='ldc-ul_cont' onclick="alter_ul_post_values(this,'6555','c_like')">Likes<img src="https://jestineyong.com/wp-content/plugins/like-dislike-counter-for-posts-pages-and-comments/images/up.png" />(<span>0</span>)</span><span class='ldc-ul_cont' onclick="alter_ul_post_values(this,'6555','c_dislike')">Dislikes<img src="https://jestineyong.com/wp-content/plugins/like-dislike-counter-for-posts-pages-and-comments/images/down.png" />(<span>0</span>)</span></div>
<div style="clear:both;"></div>
]]></content:encoded>
		
			</item>
	</channel>
</rss>
