<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>testing equipment | Electronics Repair And Technology News</title>
	<atom:link href="https://jestineyong.com/tag/testing-equipment-3/feed/" rel="self" type="application/rss+xml" />
	<link>https://jestineyong.com</link>
	<description>Semiconductors, Test Equipments, Circuit Board Troubleshooting, Electronic Repair Courses and Many More!</description>
	<lastBuildDate>Fri, 26 May 2023 22:31:02 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.4.25</generator>
	<item>
		<title>Fixing A Defect But Brand New UNI-T Tweezer Tester</title>
		<link>https://jestineyong.com/fixing-a-defect-but-brand-new-uni-t-tweezer-tester/</link>
					<comments>https://jestineyong.com/fixing-a-defect-but-brand-new-uni-t-tweezer-tester/#comments</comments>
		
		<dc:creator><![CDATA[Jestine Yong]]></dc:creator>
		<pubDate>Fri, 26 May 2023 22:31:02 +0000</pubDate>
				<category><![CDATA[Guest Post]]></category>
		<category><![CDATA[Testing Equipment]]></category>
		<category><![CDATA[testing equipment]]></category>
		<guid isPermaLink="false">https://jestineyong.com/?p=30108</guid>

					<description><![CDATA[<p>On 12 March 2023 a brand new Uni-T UT116A SMD tweezer tester was ordered from the Uni-T meter store and received about 8 days later in that month. Although everything worked it had a bad sliding function selection switch from the start that needed a lot of sliding force to move it into position. And [&#8230;]</p>
The post <a href="https://jestineyong.com/fixing-a-defect-but-brand-new-uni-t-tweezer-tester/">Fixing A Defect But Brand New UNI-T Tweezer Tester</a> first appeared on <a href="https://jestineyong.com">Electronics Repair And Technology News</a>.]]></description>
		
					<wfw:commentRss>https://jestineyong.com/fixing-a-defect-but-brand-new-uni-t-tweezer-tester/feed/</wfw:commentRss>
			<slash:comments>18</slash:comments>
		
		
			</item>
		<item>
		<title>Leaked Capacitors Caused Dim Display And ‘Low Battery’ Indication In PEAK ATLAS DCA55</title>
		<link>https://jestineyong.com/leaked-capacitors-caused-dim-display-and-low-battery-indication-in-peak-atlas-dca55/</link>
					<comments>https://jestineyong.com/leaked-capacitors-caused-dim-display-and-low-battery-indication-in-peak-atlas-dca55/#comments</comments>
		
		<dc:creator><![CDATA[Jestine Yong]]></dc:creator>
		<pubDate>Mon, 10 May 2021 02:27:07 +0000</pubDate>
				<category><![CDATA[Testing Equipment]]></category>
		<category><![CDATA[testing equipment]]></category>
		<guid isPermaLink="false">https://jestineyong.com/?p=25006</guid>

					<description><![CDATA[<p>&#160; &#160; &#160; &#160; &#160; This is my handy tool and when it showed ‘low battery’, I opened it for replacement and found that the battery had leaked and corroded the contacts. This was a few months back. I had cleaned the board thoroughly and connected it to a 12V adapter to avoid repetition of [&#8230;]</p>
The post <a href="https://jestineyong.com/leaked-capacitors-caused-dim-display-and-low-battery-indication-in-peak-atlas-dca55/">Leaked Capacitors Caused Dim Display And ‘Low Battery’ Indication In PEAK ATLAS DCA55</a> first appeared on <a href="https://jestineyong.com">Electronics Repair And Technology News</a>.]]></description>
		
					<wfw:commentRss>https://jestineyong.com/leaked-capacitors-caused-dim-display-and-low-battery-indication-in-peak-atlas-dca55/feed/</wfw:commentRss>
			<slash:comments>13</slash:comments>
		
		
			</item>
		<item>
		<title>Another Adapter Repaired 4.2V 0.5A And Tested Using Supertip</title>
		<link>https://jestineyong.com/another-adapter-repaired-4-2v-0-5a-and-tested-using-supertip/</link>
					<comments>https://jestineyong.com/another-adapter-repaired-4-2v-0-5a-and-tested-using-supertip/#comments</comments>
		
		<dc:creator><![CDATA[Jestine Yong]]></dc:creator>
		<pubDate>Fri, 22 Jan 2021 06:42:06 +0000</pubDate>
				<category><![CDATA[Guest Post]]></category>
		<category><![CDATA[Power Adapter Repair]]></category>
		<category><![CDATA[Testing Equipment]]></category>
		<category><![CDATA[testing equipment]]></category>
		<guid isPermaLink="false">https://jestineyong.com/?p=24140</guid>

					<description><![CDATA[<p>This small adapter repair was put aside for quite some time after I already had repaired all obvious defects and had also fixed a burned through copper track. And because the 4.2V 0.5A adapter board still refused to start working after all the destroyed parts were replaced I once and a while picked it up [&#8230;]</p>
The post <a href="https://jestineyong.com/another-adapter-repaired-4-2v-0-5a-and-tested-using-supertip/">Another Adapter Repaired 4.2V 0.5A And Tested Using Supertip</a> first appeared on <a href="https://jestineyong.com">Electronics Repair And Technology News</a>.]]></description>
		
					<wfw:commentRss>https://jestineyong.com/another-adapter-repaired-4-2v-0-5a-and-tested-using-supertip/feed/</wfw:commentRss>
			<slash:comments>16</slash:comments>
		
		
			</item>
		<item>
		<title>Servicing Philips TV Tester 808/TVT</title>
		<link>https://jestineyong.com/servicing-philips-tv-tester-808tvt/</link>
					<comments>https://jestineyong.com/servicing-philips-tv-tester-808tvt/#comments</comments>
		
		<dc:creator><![CDATA[Jestine Yong]]></dc:creator>
		<pubDate>Fri, 30 Dec 2016 13:44:41 +0000</pubDate>
				<category><![CDATA[Guest Post]]></category>
		<category><![CDATA[Testing Equipment]]></category>
		<category><![CDATA[testing equipment]]></category>
		<guid isPermaLink="false">https://jestineyong.com/?p=13936</guid>

					<description><![CDATA[<p>&#160; &#160; &#160; &#160; &#160; &#160; &#160; &#160; &#160; It must be somewhere around the mid of 1980s that I got a chance to include TVs in the range of electronic devices that I repaired. It was during that time, TV was introduced for the first time in Bangalore. Only B/W TVs were in the [&#8230;]</p>
The post <a href="https://jestineyong.com/servicing-philips-tv-tester-808tvt/">Servicing Philips TV Tester 808/TVT</a> first appeared on <a href="https://jestineyong.com">Electronics Repair And Technology News</a>.]]></description>
		
					<wfw:commentRss>https://jestineyong.com/servicing-philips-tv-tester-808tvt/feed/</wfw:commentRss>
			<slash:comments>17</slash:comments>
		
		
			</item>
		<item>
		<title>Accuracy, Precision and Resolution</title>
		<link>https://jestineyong.com/accuracy-precision-and-resolution/</link>
					<comments>https://jestineyong.com/accuracy-precision-and-resolution/#comments</comments>
		
		<dc:creator><![CDATA[Jestine Yong]]></dc:creator>
		<pubDate>Fri, 13 Nov 2015 03:53:52 +0000</pubDate>
				<category><![CDATA[Testing Equipment]]></category>
		<category><![CDATA[testing equipment]]></category>
		<guid isPermaLink="false">https://www.jestineyong.com/?p=11302</guid>

					<description><![CDATA[<p>&#160; &#160; &#160; &#160; &#160; &#160; &#160; While reviewing and polishing my notes for another training course in Electrical/Electronic Measurements I thought I could share this important chapter. Because the terms Accuracy, Precision and Resolution are too often confused I spent more time on this chapter than on any of the others, trying to make [&#8230;]</p>
The post <a href="https://jestineyong.com/accuracy-precision-and-resolution/">Accuracy, Precision and Resolution</a> first appeared on <a href="https://jestineyong.com">Electronics Repair And Technology News</a>.]]></description>
		
					<wfw:commentRss>https://jestineyong.com/accuracy-precision-and-resolution/feed/</wfw:commentRss>
			<slash:comments>38</slash:comments>
		
		
			</item>
	</channel>
</rss>
