Don't Miss

About Burnt Components

By on August 9, 2010

If you found one or few components burnt and after replacement and those components burnt again then you have to set a standard procedure to tackle this kind of problem. Many times components rarely burnt by itself especially the resistors. There must be a reason why the component burnt. What you must do is to check all corresponding components that lead to the burnt component. If you found a protection resistor burnt inseries to the supply line to vertical IC then you can conclude that the vertical IC shorted causing the resistor to burn.

Assuming you have check that the corresponding or  surrounding components are good then you may have to suspect other component like the switch mode transformer, flyback transformer (in CRT Monitors/Tvs) or even the high voltage transformer in LCD inverter board have shorted. Make sure the power supply output voltages are good first before checking the surrounding components.

Likes(1)Dislikes(0)

2 Comments

  1. Arnold Codilla

    August 9, 2010 at 9:11 pm

    Hello sir jestine

    How are you? hope your doing good,sir thanks your every month news letter, sir what is the common problem if the crt monitor if the LED light always orange when i turn it ON. thanks god bless
    have a nice day.

    arnold
    tech philippines

    Likes(0)Dislikes(0)
  2. admin

    August 9, 2010 at 10:05 pm

    HI ARNOLD,
    It can be the h/v wire signal broken in the cable, bad CPU or even data corrupted in EEprom IC.

    Jestine

    Likes(0)Dislikes(0)

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Open

Close