On arrival of one desktop Computer for repair to my place I found the computer is full of dust. I take out my Electric Air blower pump which I use for blow the dust. but it was not working so here my priority is to make the tool in working condition.
After primary physical visual inspection, I checked power plug for some resistance but it didn’t show any reading on the Multimeter it indicates some open circuit hence I open the unit for inspecting it from inside.
So opened top cover using flat screw driver.
Then using screwdriver, I flipped up the fan blade. Found screw underneath.
Took apart the unit for further inspection.
After opening the unit on visual inspection nothing seems doubtful. Checked On/Off switch found OK.
Then checked continuity of power cable not getting any continuity on both the line & neutral cable. From the two pin plug on power cord to the switch.
It indicates both wires are open circuit. so removed the cable on removal I found internal cores of cable is brittle and it easily getting brake on little pulling. wire is totally degraded from inside. So replaced the wire.
Connected the fan blade on motor shaft & powered On the motor & motor starts normally.
Here I made one mistake I fitted Fan Blade wrong way which I was not realize because air flow seems ok & packed the unit & finished my job of Computer Cleaning……. I realized the mistake while I was preparing this article.
But I made it right as per Company Fitting ……
This article was prepared for you by Yogesh Panchal who works as a Computer Hardware Engineer in Mumbai India.
P.S- Do you know of any your friends who would benefit from this content that you are reading now? If so, forward this website to your friends or you can invite your friends to subscribe to my newsletter for free in this Link.
Note: You can check his previous repair articles on Computer Power Ok But No Display No POST
Parasuraman S
September 15, 2022 at 8:00 am
What looks like complicated many times will get resolved by thorough check-up and simple solutions! Many thanks for sharing!
Yogesh Panchal
September 16, 2022 at 10:43 pm
You are Right Sir,
"Victory is beyond fear"......
Anwar Shiekh
September 15, 2022 at 8:28 am
Nice! hope you oiled the bearing along the way.
Yogesh Panchal
September 16, 2022 at 10:47 pm
Anwar Shiekh,
Yes, i did oiling on both the end infect this motor is not having any bearing it fitted in brass bushing.
Thanks!
Albert van Bemmelen
September 15, 2022 at 12:38 pm
Good job! Keeping our tools and equipment in good working order is imperative for quick and professional repair results.
Yogesh Panchal
September 16, 2022 at 10:52 pm
Yes, Albert,
Tools in Proper order is always being plus point for the technician.
erik blankers
September 15, 2022 at 9:19 pm
remark: The fanblade is mounted upside down by the proof of your pictures, is that correct??
Yogesh Panchal
September 16, 2022 at 11:03 pm
Erik,
Thanks for your input.....NO it is not correct , it was my mistake which i made right afterwards when i realize ....this is already mentioned in end of the article.
if you put Blade Upside down it will blow the air initially;but unit will get hot in few minutes, because it will not suck the air properly to blow.
HECTOR DELATORRE
September 15, 2022 at 9:26 pm
nice work continue to post articles.
GIFT ELIJAH
September 16, 2022 at 10:56 am
Nice fix very meticulous checks good troubleshooting leads to easy solutions.
Thanks for sharing
Yogesh Panchal
September 17, 2022 at 2:06 pm
GIFT ELIJAH,
Thanks! for your comment.
Yogesh Panchal
September 16, 2022 at 11:05 pm
Hector,
Thanks! for your comment.
Waleed Rishmawi
September 19, 2022 at 3:39 pm
good job on the repair. finding a faulty power cable is kind of nice. last week I was working on a vaccum cleaner and the cord was the problem so I could relate to that. thanks for sharing and have a blessed day
Yogesh Panchal
September 22, 2022 at 3:54 pm
Thanks! Waleed