Don't Miss

HOT Steam Vaporizer Repaired

By on September 22, 2020
hot steam vaporizer repair

 

 

 

 

 

 

 

Symptom: Not working.

how to fix hot steam vaporizer

When we plug the unit on the power there is no Light Indicator glowing and unit is not getting hot. Further inspection opened the unit no physical damage found in the unit.

how to repair hot steam vaporizer

how to service hot  steam vaporizer

So for no power symptom we have to first check the power cord. While testing the continuity with help of Multimeter I found both the wires shows open circuit. But when checked ac signal with contact less line tester it shows continuity of both the wires……how it is possible????

I removed the plug from mains and I found ….Melted Plastic on corner of the pins.

pin broken in cable

Grabbing pin with the hand I just pull the pin & pin is in my hand….

broken ac cable repair

That is why contact less line tester showing continuity because broken wire get in touch to the pin intermittently when wire having load while connected to mains socket.

Now time to replace the two pin plug. Arranged one from my junk box and replaced the same.

ac cable replacement

And connected to the mains Socket

how to fix and repair steam vaporizer

Now vaporizer start working and getting hot…..

This article was prepared for you by Yogesh Panchal who works as a Computer Hardware Engineer in Mumbai India.




P.S- Do you know of any your friends who would benefit from this content that you are reading now? If so, forward this website to your friends or you can invite your friends to subscribe to my newsletter for free in this Link.

Note: You can check his previous repair articles in the link below:

https://jestineyong.com/tip-for-triggering-any-laptop-to-switch-it-on/

 

Likes(48)Dislikes(0)

12 Comments

  1. Albert van Bemmelen

    September 22, 2020 at 7:09 pm

    Good job on fixing this Vaporizer and preventing any risk of fire because of the unreliable wiring. I guess that these Vaporizer circuits are nothing more then watercookers with adjusted boiling regulators. That instead of switching off at the reached boiling temperature probably do not reach such high temperatures and keep on heating just to produce steam? Never seen one, or used one, and neither had the opportunity to check the inside of one, nor its circuit. Although I have a steam cleaner, but that device also switches off after reaching the boiling temperature.

    Likes(4)Dislikes(0)
    • Yogesh Panchal

      September 24, 2020 at 7:56 pm

      Albert,

      You are right this vaporizer does not have any sensor or cutoff Circuit.

      It just having two metal plates as i have already shared the detail in my previous article.

      anyway i am using same steamer since last 15 Years without any problem (may be because it exhaust vapor continuously) even i continuously keep it power ON for say 30 to 45 Minutes and yes you have to switch it off manually.

      Likes(0)Dislikes(0)
      • Albert van Bemmelen

        September 25, 2020 at 12:14 am

        Thanks for that valuable and useful information Yogesh. So it doesn't use any heater coil at all, Understood!

        Likes(0)Dislikes(0)
  2. Henrique J. G. Ulbrich

    September 22, 2020 at 11:12 pm

    Never forget that a contactless device only gives just an indication, not a specific measure. Anyhow, a good job. Thanks for sharing.

    Likes(0)Dislikes(0)
    • Yogesh Panchal

      September 24, 2020 at 8:00 pm

      Henrique J. G. Ulbrich

      Thanks!

      Yes,just Visual indication..

      Likes(0)Dislikes(0)
  3. Humberto

    September 23, 2020 at 6:42 am

    Good repair. Some days more, and maybe Firemen had finished the job. Lol.

    Likes(1)Dislikes(0)
    • Yogesh Panchal

      September 24, 2020 at 8:06 pm

      Humberto,

      ha... ha....Every Man-Made inventions are too costly.for some inventions we are paying before and for some are after......

      Likes(0)Dislikes(0)
  4. Parasuraman S

    September 23, 2020 at 10:56 am

    Many thanks for sharing! Looking for a problem in mains cord is the fist step in power failure and many of us forget this!

    Likes(0)Dislikes(0)
  5. Waleed Rishmawi

    September 24, 2020 at 4:53 pm

    in a case like that, I usually add a 220 light bulb to see if it comes on or not. sometimes we get something called AC ghost which showing there is AC and actually there isn't. good job on the repair. thanks for sharing

    Likes(0)Dislikes(0)
  6. Yogesh Panchal

    September 24, 2020 at 8:17 pm

    Sir,

    You are right that's why i have opened the unit for testing continuity of the cable.

    thanks!

    Likes(0)Dislikes(0)
  7. Yogesh Panchal

    September 24, 2020 at 8:29 pm

    Waleed ,
    I think for this problem bulb also give same behavior as multi-meter reading if the wire is broken form inside.
    tip of using also good for visual inspection.
    Thanks!

    Likes(0)Dislikes(0)
  8. jackson Lor

    February 21, 2021 at 2:34 am

    nice, good job,, easy money lol,,

    thanks for sharing anyway..

    Likes(0)Dislikes(0)

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Open